목차 |
---|
syslog raw message
코드 블럭 |
---|
<171>Severity: Critical, Category: System Health, MessageID: PSU0003, Message: The power input for power supply 1 is lost. <171>Severity: Critical, Category: System Health, MessageID: RDU0012, Message: Power supply redundancy is lost. <171>Severity: Critical, Category: System Health, MessageID: PDR1016, Message: Drive 1 is removed from disk drive bay 0. <171>Severity: Critical, Category: System Health, MessageID: PDR1001, Message: Fault detected on drive 1 in disk drive bay 0. <174>Severity: Informational, Category: Storage, MessageID: PDR8, Message: Disk 5 in Enclosure 0 on Connector 0 of RAID Controller in Slot 5 is inserted. |
logstash json message
코드 블럭 |
---|
{ "@timestamp": "2022-01-18T05:18:44.048Z", "localtime": "2022-01-18 14:18:44 +0900", "ip": "172.16.0.7", "host": "14130307-bmc", "message": "<171>Severity: Critical, Category: System Health, MessageID: RDU0012, Message: Power supply redundancy is lost.\n" } { "@timestamp": "2022-01-18T05:19:01.850Z", "localtime": "2022-01-18 14:19:01 +0900", "ip": "172.16.0.7", "host": "14130307-bmc", "message": "<171>Severity: Critical, Category: System Health, MessageID: PSU0003, Message: The power input for power supply 1 is lost.\n" } { "@timestamp": "2022-01-18T05:19:01.849Z", "localtime": "2022-01-18 14:19:01 +0900", "ip": "172.16.0.7", "host": "14130307-bmc", "message": "<171>Severity: Critical, Category: System Health, MessageID: RDU0012, Message: Power supply redundancy is lost.\n" } { "@timestamp": "2022-01-18T05:19:51.918Z", "localtime": "2022-01-18 14:19:51 +0900", "ip": "172.16.0.7", "host": "14130307-bmc", "message": "<171>Severity: Critical, Category: System Health, MessageID: PDR1016, Message: Drive 1 is removed from disk drive bay 0.\n" } { "@timestamp": "2022-01-18T05:21:22.838Z", "localtime": "2022-01-18 14:21:22 +0900", "ip": "172.16.0.7", "host": "14130307-bmc", "message": "<171>Severity: Critical, Category: System Health, MessageID: PDR1001, Message: Fault detected on drive 1 in disk drive bay 0.\n" } { "@timestamp": "2022-01-18T05:21:57.056Z", "localtime": "2022-01-18 14:21:57 +0900", "ip": "172.16.0.7", "host": "14130307-bmc", "message": "<174>Severity: Informational, Category: Storage, MessageID: PDR8, Message: Disk 5 in Enclosure 0 on Connector 0 of RAID Controller in Slot 5 is inserted.\n" } |
Message format
Severity : Critical / Warning / Information
...
https://www.dell.com/support/manuals/en-us/dell-opnmang-sw-v8.0.1/eemi_13g_v1.1-v1/
Sample Logs
Sample Logs - Critical
Severity | Date and Time | Message ID | Summary | Comment |
---|---|---|---|---|
CRITICAL | 2021-07-31T06:56:46+0900 | PCI1308 | A PCI parity error was detected on a component at bus 0 device 5 function 0. | |
CRITICAL | 2022-01-18T05:18:20+0900 | PDR1001 | Fault detected on drive 1 in disk drive bay 0. | |
CRITICAL | 2021-07-30T09:43:42+0900 | PDR1016 | Drive 3 is removed from disk drive bay 1. | |
CRITICAL | 2022-01-18T05:00:26+0900 | PSU0003 | The power input for power supply 1 is lost. | |
CRITICAL | 2022-01-18T05:15:49+0900 | RDU0012 | Power supply redundancy is lost. | |
CRITICAL | 2020-05-21T15:02:56+0900 | SEC0033 | The chassis is open while the power is off. | |
CRITICAL | 2018-05-14T20:26:37+0900 | TMP0121 | The system inlet temperature is greater than the upper critical threshold. |
Sample Logs - Disk
Severity | Date and Time | Message ID | Summary | Comment |
---|---|---|---|---|
INFORMATION | 2021-07-07T03:38:12+0900 | PDR1000 | Drive 1 is installed in disk drive bay 1. | |
INFORMATION | 2021-07-07T03:38:25+0900 | PDR8 | Disk 1 in Backplane 1 of Integrated RAID Controller 1 is inserted. | |
INFORMATION | 2021-07-07T03:38:25+0900 | PDR26 | Disk 1 in Backplane 1 of Integrated RAID Controller 1 is online. | |
INFORMATION | 2021-07-07T03:38:25+0900 | PDR10 | Disk 1 on Integrated RAID Controller 1 rebuild has started. | |
CRITICAL | 2021-07-07T03:38:27+0900 | PDR1001 | Fault detected on drive 1 in disk drive bay 1. | |
INFORMATION | 2021-07-07T03:38:32+0900 | PDR1017 | Drive 1 in disk drive bay 1 is operating normally. | |
INFORMATION | 2021-07-07T04:45:36+0900 | PDR15 | Disk 1 in Backplane 1 of Integrated RAID Controller 1 rebuild is complete. | |
INFORMATION | 2021-07-07T04:45:36+0900 | VDR2 | Virtual Disk 0 on Integrated RAID Controller 1 returned to optimal state. | |
INFORMATION | 2021-07-07T08:10:52+0900 | PDR15 | Disk 3 in Backplane 1 of Integrated RAID Controller 1 rebuild is complete. | |
INFORMATION | 2021-07-07T08:10:52+0900 | VDR2 | Virtual Disk 1 on Integrated RAID Controller 1 returned to optimal state. | |
INFORMATION | 2021-07-30T09:19:59+0900 | PR36 | Version change detected for Physical Disk 0:1:2 firmware. Previous version:RS11, Current version:C3D0 | |
CRITICAL | 2021-07-30T09:43:42+0900 | PDR1016 | Drive 3 is removed from disk drive bay 1. | |
INFORMATION | 2021-07-31T06:49:52+0900 | PDR26 | Disk 0 in Backplane 1 of Integrated RAID Controller 1 is online. | |
INFORMATION | 2021-07-31T06:49:52+0900 | PDR26 | Disk 1 in Backplane 1 of Integrated RAID Controller 1 is online. | |
INFORMATION | 2021-07-31T06:49:52+0900 | PDR26 | Disk 2 in Backplane 1 of Integrated RAID Controller 1 is online. | |
INFORMATION | 2021-07-31T06:49:52+0900 | PDR26 | Disk 4 in Backplane 1 of Integrated RAID Controller 1 is online. | |
INFORMATION | 2021-07-31T06:49:52+0900 | VDR4 | Virtual Disk 0 on Integrated RAID Controller 1 was created. | |
INFORMATION | 2021-07-31T06:50:43+0900 | PDR107 | Disk 6 in Backplane 1 of Integrated RAID Controller 1 is assigned as global hot spare. | |
INFORMATION | 2021-07-31T06:52:52+0900 | VDR32 | Background initialization has started for Virtual Disk 0 on Integrated RAID Controller 1. | |
INFORMATION | 2021-07-31T06:54:36+0900 | CTL1 | Controller event log: Background initialization has started for Virtual Disk 0 on Integrated RAID Controller 1. | |
INFORMATION | 2021-07-31T08:26:52+0900 | CTL1 | Controller event log: Background initialization has started for Virtual Disk 0 on Integrated RAID Controller 1. | |
INFORMATION | 2021-07-31T08:51:12+0900 | CTL1 | Controller event log: Background initialization has started for Virtual Disk 0 on Integrated RAID Controller 1. | |
INFORMATION | 2021-08-01T05:22:12+0900 | VDR35 | Background initialization has completed for Virtual Disk 0 on Integrated RAID Controller 1. | |
INFORMATION | 2022-01-18T05:16:49+0900 | PDR1016 | Drive 1 is removed from disk drive bay 0. | |
CRITICAL | 2022-01-18T05:18:20+0900 | PDR1001 | Fault detected on drive 1 in disk drive bay 0. | |
INFORMATION | 2022-01-18T05:18:54+0900 | PDR8 | Disk 5 in Enclosure 0 on Connector 0 of RAID Controller in Slot 5 is inserted. |
...