1. 서버 납품정보 회신

납품 전 이메일로 개요와 상세정보를 회신하고, 
납품 후 설치 사진을 이메일로 회신

1.1. 개요 정보 회신

이메일에 IPMI ID, IPMI PW, ROOT PW 회신

하기 표를 엑셀로 정리하여 송부

납품처

납품처 태그 번호제조사모델명시리얼 번호IPMI MAC비고
총판 및 납품처 정보 기입하기 참고

하기 참고하기 참고







1.2. 상세 정보 회신

서버마다 < inxi -F > 커맨드의 결과를 < inxi-제조사-모델-시리얼번호.txt > 으로 저장하여 회신

# sudo inxi -F
System:
  Host: localhost Kernel: 4.18.0-372.9.1.el8.x86_64 arch: x86_64 bits: 64 Console: pty pts/4
    Distro: Rocky Linux release 8.6 (Green Obsidian)
Machine:
  Type: Kvm System: Supermicro product: SYS-2029U-TN24R4T v: 0123456789 serial: A264025X0A02724
  Mobo: Supermicro model: X11DPU v: 1.10 serial: OM204S054199 UEFI: American Megatrends v: 3.4
    date: 10/30/2020
CPU:
  Info: 2x 12-core model: Intel Xeon Gold 6246 bits: 64 type: MT MCP SMP cache:
    L2: 2x 12 MiB (24 MiB)
  Speed (MHz): avg: 2984 min/max: 1200/4200 cores: 1: 3117 2: 3125 3: 1200 4: 2171 5: 1480
    ...
Graphics:
  Device-1: ASPEED Graphics Family driver: ast v: kernel
  Display: server: X.org v: 1.20.11 with: Xwayland v: 21.1.3 driver: X: loaded: modesetting
    unloaded: fbdev,vesa gpu: ast tty: 209x12 resolution: 1920x1080
Audio:
  Message: No device data found.
  Sound Server-1: PulseAudio v: 14.0-rebootstrapped running: yes
Network:
  Device-1: Intel Ethernet 10G X550T driver: ixgbe
  IF: eno1 state: down mac: ac:1f:6b:c8:63:40
  Device-2: Intel Ethernet 10G X550T driver: ixgbe
  IF: eno2 state: down mac: ac:1f:6b:c8:63:41
  Device-3: Intel Ethernet 10G X550T driver: ixgbe
  IF: eno3 state: down mac: ac:1f:6b:c8:63:42
  Device-4: Intel Ethernet 10G X550T driver: ixgbe
  IF: eno4 state: down mac: ac:1f:6b:c8:63:43
  Device-5: Mellanox MT27800 Family [ConnectX-5] driver: mlx5_core
  IF: ens1 state: up speed: 100000 Mbps duplex: full mac: 04:3f:72:cf:d4:02
RAID:
  Hardware-1: Intel Volume Management Device NVMe RAID Controller driver: vmd
  Hardware-2: Intel Volume Management Device NVMe RAID Controller driver: vmd
  Hardware-3: Intel Volume Management Device NVMe RAID Controller driver: vmd
  Hardware-4: Intel Volume Management Device NVMe RAID Controller driver: vmd
  Hardware-5: Intel Volume Management Device NVMe RAID Controller driver: vmd
  Hardware-6: Intel Volume Management Device NVMe RAID Controller driver: vmd
  Device-1: md125 type: mdraid level: raid-5 status: active size: 6.91 TiB report: 9/9 UUUUUUUUU
  Components: Online: 0: nvme9n1 1: nvme8n1 2: nvme7n1 3: nvme6n1 4: nvme5n1 5: nvme4n1
    6: nvme3n1 7: nvme2n1 8: nvme1n1
  Device-2: md126 type: mdraid level: N/A status: inactive size: N/A report: N/A
  Components: Online: N/A Spare: 0: nvme10n1
  Device-3: md127 type: mdraid level: N/A status: inactive size: N/A report: N/A
  Components: Online: N/A Spare: 0: nvme5n1 1: nvme4n1 2: nvme8n1 3: nvme3n1 4: nvme1n1
    5: nvme2n1 6: nvme9n1 7: nvme7n1 8: nvme6n1
Drives:
  Local Storage: total: raw: 9.56 TiB usable: -867393600 used: 40.27 GiB
  ID-1: /dev/nvme0n1 vendor: Samsung model: SSD 970 PRO 512GB size: 476.94 GiB
  ID-2: /dev/nvme10n1 vendor: Intel model: SSDPE2KX010T8 size: 931.51 GiB
  ID-3: /dev/nvme1n1 vendor: Intel model: SSDPE2KX010T8 size: 931.51 GiB
  ID-4: /dev/nvme2n1 vendor: Intel model: SSDPE2KX010T8 size: 931.51 GiB
  ID-5: /dev/nvme3n1 vendor: Intel model: SSDPE2KX010T8 size: 931.51 GiB
  ID-3: /boot/efi size: 598.8 MiB used: 5.8 MiB (1.0%) fs: vfat dev: /dev/nvme0n1p1
Swap:
  ID-1: swap-1 type: partition size: 4 GiB used: 1.02 GiB (25.4%) dev: /dev/dm-1
Sensors:
  Src: ipmi System Temperatures: cpu-1: 51 C cpu-2: 53 C mobo: 28 C
  Fan Speeds (RPM): fan-1: 3400 fan-2: 3400 fan-7: 3900 fan-8: 3900
  Src: lm-sensors System Temperatures: cpu: 47.0 C mobo: N/A
  Fan Speeds (RPM): N/A
Info:
  Processes: 743 Uptime: 23d 19h 3m Memory: 187.32 GiB used: 175.38 GiB (93.6%) Init: systemd
  target: graphical (5) Shell: Zsh inxi: 3.3.24

1.3. KISTI 자산태그 부착 후 사진 회신

서버 전면에 KISTI 자산태그 부착

부착할 공간이 없으면 네임타이 부착 후 KISTI 자산태그 부착


(참고) 총판/납품처 태그 확인

(참고) 제조사 시리얼 (서비스 태그) 확인

상기 엑셀시트에 기입하는 것은, 서버에 붙어있는 서비스태그로 확인한 시리얼과 리눅스 커맨드로 확인한 시리얼이 동일한지 확인 후 기입

리눅스에서 서비스 태그(시리얼) 조회하기
# sudo inxi -F | grep serial
  Type: Kvm System: Supermicro product: SYS-2029U-TN24R4T v: 0123456789 serial: A264025X0A02724
  Mobo: Supermicro model: X11DPU v: 1.10 serial: OM204S054199 UEFI: American Megatrends v: 3.4

(참고) IPMI 맥 확인

1) 제조사가 서버에 붙인 스티커나 서비스 태그에 기입된 경우가 있음

2) 리눅스 명령어로 확인

# ipmitool lan print 1
IP Address Source       : DHCP Address
IP Address              : 192.168.0.29
MAC Address             : 3c:ec:ef:18:88:d4
...


2. 서버 IPMI 설정

IPMI 주소dhcp# sudo ipmitool lan set 1 ipsrc dhcp
ID임의
PW임의


3. 서버 OS, SW, 드라이버 설치

하기 납품가이드 참고

Rocky Linux 8 설치 가이드 (납품용)

perfSONAR 설치 가이드 (납품용)

  • 레이블 없음