syslog raw message

<171>Severity: Critical, Category: System Health, MessageID: PSU0003, Message: The power input for power supply 1 is lost.
<171>Severity: Critical, Category: System Health, MessageID: RDU0012, Message: Power supply redundancy is lost.
<171>Severity: Critical, Category: System Health, MessageID: PDR1016, Message: Drive 1 is removed from disk drive bay 0.
<171>Severity: Critical, Category: System Health, MessageID: PDR1001, Message: Fault detected on drive 1 in disk drive bay 0.
<174>Severity: Informational, Category: Storage, MessageID: PDR8, Message: Disk 5 in Enclosure 0 on Connector 0 of RAID Controller in Slot 5 is inserted.


logstash json message

{
    "@timestamp": "2022-01-18T05:18:44.048Z",
    "localtime": "2022-01-18 14:18:44 +0900",
    "ip": "172.16.0.7",
    "host": "14130307-bmc",
    "message": "<171>Severity: Critical, Category: System Health, MessageID: RDU0012, Message: Power supply redundancy is lost.\n"
}
{
    "@timestamp": "2022-01-18T05:19:01.850Z",
    "localtime": "2022-01-18 14:19:01 +0900",
    "ip": "172.16.0.7",
    "host": "14130307-bmc",
    "message": "<171>Severity: Critical, Category: System Health, MessageID: PSU0003, Message: The power input for power supply 1 is lost.\n"
}
{
    "@timestamp": "2022-01-18T05:19:01.849Z",
    "localtime": "2022-01-18 14:19:01 +0900",
    "ip": "172.16.0.7",
    "host": "14130307-bmc",
    "message": "<171>Severity: Critical, Category: System Health, MessageID: RDU0012, Message: Power supply redundancy is lost.\n"
}
{
    "@timestamp": "2022-01-18T05:19:51.918Z",
    "localtime": "2022-01-18 14:19:51 +0900",
    "ip": "172.16.0.7",
    "host": "14130307-bmc",
    "message": "<171>Severity: Critical, Category: System Health, MessageID: PDR1016, Message: Drive 1 is removed from disk drive bay 0.\n"
}
{
    "@timestamp": "2022-01-18T05:21:22.838Z",
    "localtime": "2022-01-18 14:21:22 +0900",
    "ip": "172.16.0.7",
    "host": "14130307-bmc",
    "message": "<171>Severity: Critical, Category: System Health, MessageID: PDR1001, Message: Fault detected on drive 1 in disk drive bay 0.\n"
}
{
    "@timestamp": "2022-01-18T05:21:57.056Z",
    "localtime": "2022-01-18 14:21:57 +0900",
    "ip": "172.16.0.7",
    "host": "14130307-bmc",
    "message": "<174>Severity: Informational, Category: Storage, MessageID: PDR8, Message: Disk 5 in Enclosure 0 on Connector 0 of RAID Controller in Slot 5 is inserted.\n"
}


Message format

Severity : Critical / Warning / Information


Event and Error Message Reference Guide for 13th Generation Dell PowerEdge Servers Version 1.1

https://www.dell.com/support/manuals/en-us/dell-opnmang-sw-v8.0.1/eemi_13g_v1.1-v1/


Sample Logs

idrac-log-sample.xlsx

Sample Logs - Critical

SeverityDate and TimeMessage IDSummaryComment
CRITICAL2021-07-31T06:56:46+0900PCI1308A PCI parity error was detected on a component at bus 0 device 5 function 0.
CRITICAL2022-01-18T05:18:20+0900PDR1001Fault detected on drive 1 in disk drive bay 0.
CRITICAL2021-07-30T09:43:42+0900PDR1016Drive 3 is removed from disk drive bay 1.
CRITICAL2022-01-18T05:00:26+0900PSU0003The power input for power supply 1 is lost.
CRITICAL2022-01-18T05:15:49+0900RDU0012Power supply redundancy is lost.
CRITICAL2020-05-21T15:02:56+0900SEC0033The chassis is open while the power is off.
CRITICAL2018-05-14T20:26:37+0900TMP0121The system inlet temperature is greater than the upper critical threshold.


Sample Logs - Disk

SeverityDate and TimeMessage IDSummaryComment
INFORMATION2021-07-07T03:38:12+0900PDR1000Drive 1 is installed in disk drive bay 1.
INFORMATION2021-07-07T03:38:25+0900PDR8Disk 1 in Backplane 1 of Integrated RAID Controller 1 is inserted.
INFORMATION2021-07-07T03:38:25+0900PDR26Disk 1 in Backplane 1 of Integrated RAID Controller 1 is online.
INFORMATION2021-07-07T03:38:25+0900PDR10Disk 1 on Integrated RAID Controller 1 rebuild has started.
CRITICAL2021-07-07T03:38:27+0900PDR1001Fault detected on drive 1 in disk drive bay 1.
INFORMATION2021-07-07T03:38:32+0900PDR1017Drive 1 in disk drive bay 1 is operating normally.
INFORMATION2021-07-07T04:45:36+0900PDR15Disk 1 in Backplane 1 of Integrated RAID Controller 1 rebuild is complete.
INFORMATION2021-07-07T04:45:36+0900VDR2Virtual Disk 0 on Integrated RAID Controller 1 returned to optimal state.
INFORMATION2021-07-07T08:10:52+0900PDR15Disk 3 in Backplane 1 of Integrated RAID Controller 1 rebuild is complete.
INFORMATION2021-07-07T08:10:52+0900VDR2Virtual Disk 1 on Integrated RAID Controller 1 returned to optimal state.
INFORMATION2021-07-30T09:19:59+0900PR36Version change detected for Physical Disk 0:1:2 firmware. Previous version:RS11, Current version:C3D0
CRITICAL2021-07-30T09:43:42+0900PDR1016Drive 3 is removed from disk drive bay 1.
INFORMATION2021-07-31T06:49:52+0900PDR26Disk 0 in Backplane 1 of Integrated RAID Controller 1 is online.
INFORMATION2021-07-31T06:49:52+0900PDR26Disk 1 in Backplane 1 of Integrated RAID Controller 1 is online.
INFORMATION2021-07-31T06:49:52+0900PDR26Disk 2 in Backplane 1 of Integrated RAID Controller 1 is online.
INFORMATION2021-07-31T06:49:52+0900PDR26Disk 4 in Backplane 1 of Integrated RAID Controller 1 is online.
INFORMATION2021-07-31T06:49:52+0900VDR4Virtual Disk 0 on Integrated RAID Controller 1 was created.
INFORMATION2021-07-31T06:50:43+0900PDR107Disk 6 in Backplane 1 of Integrated RAID Controller 1 is assigned as global hot spare.
INFORMATION2021-07-31T06:52:52+0900VDR32Background initialization has started for  Virtual Disk 0 on Integrated RAID Controller 1.
INFORMATION2021-07-31T06:54:36+0900CTL1Controller event log: Background initialization has started for  Virtual Disk 0 on Integrated RAID Controller 1.
INFORMATION2021-07-31T08:26:52+0900CTL1Controller event log: Background initialization has started for  Virtual Disk 0 on Integrated RAID Controller 1.
INFORMATION2021-07-31T08:51:12+0900CTL1Controller event log: Background initialization has started for  Virtual Disk 0 on Integrated RAID Controller 1.
INFORMATION2021-08-01T05:22:12+0900VDR35Background initialization has completed for  Virtual Disk 0 on Integrated RAID Controller 1.
INFORMATION2022-01-18T05:16:49+0900PDR1016Drive 1 is removed from disk drive bay 0.
CRITICAL2022-01-18T05:18:20+0900PDR1001Fault detected on drive 1 in disk drive bay 0.
INFORMATION2022-01-18T05:18:54+0900PDR8Disk 5 in Enclosure 0 on Connector 0 of RAID Controller in Slot 5 is inserted.